Skip to main content
. 2012 Nov 13;12:259. doi: 10.1186/1471-2180-12-259

Table 1.

Bacteria quantification methods

Method Range of detection Time to obtain results Distinguishes live vs. dead Persisters included in quantification Applications Equipment needed Count affected by minor bacterial clumps
CFU count
Unlimited
Days
Yes
Yes
Determination of absolute bacterial number
None
Yes
Absorbance
108–1010 bacteria/mL
Immediate
No
No
Follow growth curves
Spectrophotometer or plate reader
No
Microscopy
Unlimited
Minutes
Yes, with staining
No
Determination of absolute bacterial number
Microscope
No
Flow cytometry
> ~5000
Minutes
Yes, with staining
Yes, if not below detection
Determination of absolute bacterial number
FACS
Yes
MBRT [2]
> ~107
Hours
Yes
No (metabolically quiescent cells missed)
MIC and MAC determination
Spectrophotometer
No
SGT Unlimited Hours Yes Yes HTS, persister Quantification Plate reader No