Skip to main content
. Author manuscript; available in PMC: 2014 Feb 1.
Published in final edited form as: J Orthop Res. 2012 Aug 31;31(2):173–182. doi: 10.1002/jor.22214

Table 2.

Group 1 Pre vs Post operative range of motion measurements demonstrate significantly increased ranges of motion following hip arthroplasty.

Group 1 (n=21) Pre-Op Post-Op* P value**
Flexion 104 (70–140) 128 (110–145) p<0.0001
Flexion contracture 19 (0–65) 1 (0–5) p<0.0001
Abd (in extension) 27 (−20–60) 48 (30–60) p<0.0001
Add (in extension) 20 (5–45) 32 (10–45) p<0.0001
Internal Rotation 3 (−10–30) 48 (15–60) p<0.01
External Rotation 11 (−10–35) 47 (30–90) p<0.01
Rotation Arc 23 (0–75) 93 (65–145) p<0.0001
SF-12 36.7 (25.0–56.2) 53.7 (29.6–66.7) P<0.0008
SF-12 (Group 2) 29.6 (17.0–41.4) 49.5 (28.7–59.4) p<0.0001
*

At last follow-up average 2.26 (1–4) years post operative

**

Wilcoxon (one-tailed, matched pair) statistical comparison.