Table 3. Comparison of the performance of different peak picking methods.
Spectra | 15N-HSQC | HNCO | HNCA | HNCACB | CBCA(CO)NH | ||||||
Method | Rec | Pre | Rec | Pre | Rec | Pre | Rec | Pre | Rec | Pre | F – score |
PICKY | 93 | 81 | 89 | 74 | 88 | 74 | 60 | 78 | 72 | 66 | 77 |
WaVPeak | 96 | 80 | 91 | 76 | 88 | 74 | 76 | 64 | 85 | 71 | 80 |
B-H (WaVPeak) | 97 | 70 | 92 | 73 | 89 | 76 | 76 | 71 | 87 | 67 | 79 |
Consensus () | 97 | 72 | 92 | 70 | 88 | 82 | 77 | 72 | 88 | 69 | 80 |
B-H (Consensus) | 97 | 83 | 89 | 80 | 86 | 93 | 76 | 84 | 86 | 80 | 85 |
Rec stands for recall values and Pre stands for precision values. The recall and the precision values of PICKY and WaVPeak are taken from [1]. B-H (WaVPeak) is the WaVPeak peaks selected by the proposed B-H algorithm. Consensus () is the consensus of WaVPeak and PICKY by simply considering the top peaks from each method. B-H (Consensus) is the consensus of WaVPeak and PICKY by considering the top peaks that are determined by the proposed B-H algorithm. All the values are given as percentage.