Skip to main content
. 2012 Oct 17;12(10):14004–14021. doi: 10.3390/s121014004

Table 2.

Data Estimation results (% error ANN/% error interpolation) for Humidity (H) in Sensor 3 (S3), combining Temperature (T) and Humidity in Sensors 1 and 2 (S1 and S2) as input.

Input T No T used T at S1 T at S2 T at S1 & S2
Input H
No H used 6.48%/NA 5.92%/NA 5.78%/NA
H at S1 7.30%/33.43% 4.95%/33.43% 5.66%/33.43% 4.46%/33.43%
H at S2 5.36%/28.72% 5.19%/28.72% 5.59%/28.72% 5.32%/28.72%
H at S1 & S2 6.97%/28.72% 4.80%/28.72% 6.51%/28.72% 4.98%/28.72%