Skip to main content
. 2012 Dec 12;9(12):4639–4662. doi: 10.3390/ijerph9124639

Table 6.

Relative sensitivity of model parameters on predicted concentrations in living area (LR) and bedroom (BR) for six scenarios (scenario number in parentheses). Absolute values greater than 0.40 are shown in bold.

Para-meter Units Emissions in Living Area Emissions in Bedroom No Indoor Emissions
No Filter (1) W/Filter (1F) No Filter (2) W/Filter (2F) No Filter (3) W/Filter (3F)
LR BR LR BR LR BR BR LR BR LR BR
Predicted concentrations
C1 µg·m−3 24 - 22 - 20 - 8 - 4 - 4 -
C2 µg·m−3 - 15 - 4 - 78 - 21 - 5 - 1
Relative sensitivity
E1 µg·h−1 0.82 0.69 0.83 0.69 - - - - - - - -
E2 µg·h−1 - - - - 0.78 0.94 0.54 0.94 - - - -
Q1 m3·h−1 −0.50 −0.42 −0.45 −0.37 −0.47 −0.06 −0.18 −0.01 0.16 0.08 0.30 0.13
Q2 m3·h−1 −0.04 −0.29 0.00 0.05 −0.36 −0.43 −0.05 −0.09 0.02 0.08 0.03 0.44
Q3 m3·h−1 0.05 0.35 0.03 0.69 −0.35 −0.41 −0.06 −0.10 −0.01 −0.03 0.02 0.30
Q4 m3·h−1 −0.09 −0.08 −0.18 −0.15 0.69 0.09 0.36 0.02 0.01 0.01 −0.15 −0.06
CoutkP,1 µg·m−3 0.16 0.13 0.16 0.13 0.19 0.03 0.44 0.03 0.87 0.42 0.96 0.42
CoutkP,2 µg·m−3 0.02 0.18 0.01 0.18 0.03 0.03 0.02 0.03 0.13 0.58 0.04 0.58
kD,1 h−1 −0.19 −0.16 −0.17 −0.14 −0.19 −0.03 −0.17 −0.01 −0.19 −0.09 −0.17 −0.08
kD,2 h−1 −0.01 −0.05 0.00 −0.01 −0.05 −0.05 −0.01 −0.01 −0.01 −0.05 0.00 −0.01
V1 m3 −0.19 −0.16 −0.17 −0.14 −0.19 −0.03 −0.17 −0.01 −0.19 −0.09 −0.17 −0.08
V2 m3 −0.01 −0.05 0.00 −0.01 −0.05 −0.05 −0.01 −0.01 −0.01 −0.06 0.00 −0.02
ηF2QF2 m3·h−1 - - −0.03 −0.68 - - −0.39 −0.68 - - −0.05 −0.68