Table 1. Mechanical properties of the c-pclt polyester samples.
SAMPLE | TENSILE STRENGTH (MPa) |
% ELONGATION AT BREAK (%) |
YOUNGS MODULUS (MPa) |
MODULUS OF TOUGHNESS (KPa) |
---|---|---|---|---|
1:1 C-PCLT |
1.46 ± 0.27 |
61 ± 07 |
2.44 ± 0.26 |
7.61 ± 1.13 |
3:2 C-PCLT |
1.12 ± 0.19 |
177 ± 15 |
0.56 ± 0.12 |
13.20 ± 0.87 |
2:1 C-PCLT | 1.73 ± 0.22 | 146 ± 16 | 1.08 ± 0.16 | 15.08 ± 1.16 |