Skip to main content
. 2012 Nov 11;16(2):116–122. doi: 10.1093/icvts/ivs461

Table 3:

Findings on MRI after transapical and surgical aortic valve replacement

TA-TAVI (n = 12) AVR (n = 35) P-value
Patients with new lesions 7 (58) 12 (34) 0.131
Total number of lesions 22 37 0.224
Localization
 Frontal 14 (64) 9 (24) 0.003
 Parietal 1 (5) 2 (5) 0.451
 Occipital 4 (18) 10 (27) 0.192
 Temporal 1 (5) 1 (3) 0.476
 Cerebellum 2 (9) 10 (27) 0.072
 Others 0 5 (14) 0.087
Patients with single lesion 1 (8) 3 (9) 0.397
Patients with multiple lesions 6 (50) 9 (26) 0.525
Patients with bihemispheric lesions 5 (42) 6 (17) 0.465
Embolic lesions per patient 1.8 ± 1.9 (0–5) 1.1 ± 1.9 (0–7) 0.149
Single lesion volume (mm3) 171.7 ± 282.9 (15–1205) 218.6 ± 437.3 (50–1900) 0.713
Time of postprocedural scan (days) 11.7 ± 6.2 (6–26) 6.5 ± 3.0 (2–32) 0.016

Categorical data are given as frequency (percentage) and continuous data as mean ± SD (range).