Skip to main content
. 2012 Dec;17(10):549–552. doi: 10.1093/pch/17.10.549

TABLE 4.

Test properties of the Rourke Baby Record and the Nipissing District Developmental Screen (NDDS) compared with the Bayley Scales of Infant Development III (BSITD-III) (≤70)* at one and two flag cut-points

Sens Spec PPV NPV False positive False negative LR+ Acc
Rourke
  One flag 100 72 20 100 28 0 3.6 74
  Two flags 100 90 40 100 10 0 9.7 90
NDDS
  One flag 100 76 22 100 24 0 4.1 77
  Two flags 100 93 50 100 7 0 14.5 94

Data presented as %, except for the likelihood ratio of a positive test (LR+).

*

A score of ≤70 (two SDs below the mean) on the BSITD-III was assessed to determine whether the test characteristics differed when using a more impaired definition of delay.

A ‘No’ response, indicating that the child did not demonstrate the skill, was termed a ‘flag’. Acc Accuracy; NPV Negative predictive value; PPV Positive predictive value; Sens Sensitivity, Spec Specificity