Table 1.

Patient information and model dimensions

Patient Model S1 S2
Patient age (years old) 8 8
Body Surface Area (m2) 0.95 1.25
MRI Acquisition Parameters Sequence TrueFISP # TrueFISP #
No. of Slices 40 35
Slice Dimension 84 × 128 168 × 256
Pixel Spacing (mm) 1.875 × 1.875 1.25 × 1.25
Slice Thickness (mm) 4 5
Repetition Time, Echo Time (ms) 146.80, 1.11 195.50, 1.24
PCMRI Acquisition Parameters Encoding velocity (cm/s) 80 80
No. of Phases 20 45
Diagnosis* HLHS DILV, PulA
SVC Anastomosis Hemi-Fontan Bidirectional Glenn
IVC Anastomosis Fenestrated intra-atrial Fenestrated extra-cardiac
Vessel cross section area (mm2) IVC 358 294
SVC 163 91
LPA 13 75
RPA 95 71
*

Notation: HLHS = hypoplastic left heart syndrome, DILV = double inlet left ventricle, PulA = pulmonary atresia

#

The data was acquired during breath-hold (respiratory influence neglected).