Skip to main content
. 2013 Jan 2;8:3. doi: 10.1186/1748-717X-8-3

Table 2.

Dose volume constraints for anatomic planning and functional planning used for intensity-modulated radiotherapy (IMRT)

 
 
Anatomic planning
Functional planning
Structure Constraint type Dose Volume (%) Priority Dose Volume (%) Priority
GTV
Maximum dose
105%
0%
50
105%
0%
50
Minimum dose
103%
100%
450
103%
100%
450
CTV
Maximum dose
105%
0%
400
105%
0%
400
Minimum dose
102%
100%
400
102%
100%
400
PTV
Maximum dose
105%
0%
650
105%
0%
650
Minimum dose
101%
100%
350
101%
100%
350
Total lung
Maximum dose
5 Gy
30%
200
5 Gy
30%
200
Maximum dose
10 Gy
25%
200
10 Gy
25%
200
Maximum dose
20 Gy
20%
200
20 Gy
20%
200
Functional lung
Maximum dose
 
 
 
5 Gy
30%
250
Maximum dose
 
 
 
10 Gy
25%
250
Maximum dose
 
 
 
20 Gy
20%
250
Spinal cord
Maximum dose
40 Gy
0%
300
40 Gy
0%
300
Spinal cord + 5 mm Maximum dose 45 Gy 0% 300 45 Gy 0% 300