Skip to main content
. 2013 Jan 7;11:1. doi: 10.1186/1476-7120-11-1

Table 2.

Echocardiographic results and follow up (*1 patient with an event 10 days after CV was excluded due to discontinuation of anticoagulation; abbreviations see text)

  Contrast-enhanced TEE Control group p value
n
90
90
 
thrombus detected (%)
10 (11.1)
10 (11.1)
 
LAA-flow (m/s)
0.32 ±0.2
0.29 ±0.2
0.75
LAA-flow ≤ 0.3m/s (%)
7 (70)
8 (80)
0.606
SEC (no/minor-moderate/ marked)
2 / 6 / 2
0 / 4 / 6
0.111
LA diameter (mm)
47.6±7.2
50.1±6.1
0.429
thrombus excluded / unclear
80 (88.9)
80 (88.9)
 
LAA-flow (m/s)
0.47 ±0.2
0.48 ±0.2
0.711
SEC (no/minor-moderate/ marked)
35 / 38 / 7
25 / 48 / 7
0.243
LA diameter (mm)
46.5±6.3
46.6±7.3
0.895
CV performed (%)
74 (82.2)
76 (84.4)
0.514
CV related events (%) 0 (0)* 3 (3.9) 0.084