Table 2.
Liposome | Mean diameter (nm) | Polydispersity index | Zeta potential (mV) |
---|---|---|---|
Non-filtered | |||
SCF-S100 | 1137.96 ± 131.39 | 0.34 ± 0.02 | −7.73 ± 3.38 |
SCF-E80 | 747.04 ± 82.30 | 0.30 ± 0.03 | −30.77 ± 7.00 |
Film-S100 | 2155.90 ± 373.55 | 0.61 ± 0.09 | −7.92 ± 5.55 |
Film-E80 | 1543.01 ± 66.31 | 0.51 ± 0.10 | −22.4 ± 9.33 |
Filtered | |||
SCF-S100 | 188.93 ± 17.00 | 0.22 ± 0.02 | −6.82 ± 2.96 |
SCF-E80 | 166.58 ± 9.60 | 0.18 ± 0.01 | −30.72 ± 1.92 |
Film-S100 | 244.30 ± 44.15 | 0.22 ± 0.02 | −5.76 ± 0.56 |
Film-E80 | 198.87 ± 26.24 | 0.20 ± 0.03 | −19.25 ± 6.12 |
Notes: “Filtered” represents liposomes passed through a 1.0 μm pore size PTFE syringe filter before analysis. Values denote the mean ± standard deviation of six separate sets of experiments.
Abbreviations: SCF-CO2, supercritical fluid of carbon dioxide; SCF-S100, supercritical fluid liposomes prepared using Lipoid S100; SCF-E80, supercritical fluid liposomes prepared using Lipoid E80; Film-S100, conventional liposomes prepared using Lipoid S100; Film-E80, conventional liposomes prepared using Lipoid E80; PTFE, polytetrafluoroethylene.