Skip to main content
. 2013 Jan 29;8(1):e55329. doi: 10.1371/journal.pone.0055329

Table 1. Parameters of activation, voltage-dependence and time-dependent inactivation under control conditions and in the presence of PHT.

Control PHT 100μM
Activation (n = 21; LV and LII-III pooled)
V½ (mV) −43.6±0.9 −44.6±1.2
K (mV) 3.1±0.1 3.2±0.2
Steady state inactivation (n = 6, pooled))
V½ (mV) −35.3±1.1 −44.3±1.3**
K (mV) 9.1±1.2 7.3±0.5
Time dependent inactivation
Layer V at -20mV(n = 10) τ1 (ms) 680±120 330±50**
1 (%) 28±3 29±4
τ2 (ms) 9000±1500 6800±800*
2 (%) 44±4 45±4
Baseline (%) 27±3 25±4
Layer V at +40mV (n = 9) τ1 (ms) 167±24 115±20*
1 (%) 30±4 39±5
τ2 (ms) 4873±375 1850±321*
2 (%) 54±6 45±5
Baseline (%) 16±3 16±4
Layer II-III at -20mV (n = 8) τ1 (ms) 350±70 125±40*
1 (%) 28±2 31±3
τ2 (ms) 8800±500 4800±600*
2 (%) 45±3 43±4
Baseline (%) 24±2 23±3
*

 = p<0.05;** =  p<0.01 (paired t-test). These values have not been corrected for the junction potential error (see Methods).

HHS Vulnerability Disclosure