Skip to main content
. 2013 Jan 31;14:1. doi: 10.1186/1467-4866-14-1

Table 2.

Summary of selected resin separation tests including treatment steps and outcome

Resin Column Type Oxic or anoxic conditions Ti(III) treatment Initial [Utot] (μM)a UtotRecovered (%)a Initial U(IV) (%) Initial U(VI) (%) Recovered as U(IV) (%)b Recovered as U(VI) (%)b
Bio-Rad AG1x8 prefilled
Bio-Rad Poly-prep
Oxic
No
2.1
72
0
100
0
100
Bio-Rad AG1x8 prefilled
Bio-Rad Poly-prep
Oxic
No
22.2
86
0
100
0
100
Bio-Rad AG1x8 powder
Bio-Rad Poly-prep
Oxic
No
2.1
92
0
100
0
100
Dowex 1x8 powder
Bio-Rad Poly-prep
Oxic
No
2.1
100
0
100
0
100
Dowex 1x8 powder
Pierce polystyrene
Oxic
No
2.1
100
0
100
0
100
Bio-Rad AG1x8 prefilled
Bio-Rad Poly-prep
Anoxic
No
2.1
81
36
64
0
100
Dowex 1x8 powder
Pierce polystyrene
Anoxic
No
8.7
100
98
2
86
14
Dowex 1x8 powder
Pierce polystyrene
Anoxic
Yes
8.7
100
98
2
98
2
Dowex 1x8 powder
Pierce polystyrene
Anoxic
Yes
1.8
100
0
100
0
100
Dowex 1x8 powder
Pierce polystyrene
Anoxic
Yes
2.8
100
100
0
100
0
Dowex 1x8 powder
Pierce polystyrene
Anoxic
Yes
2.1
100
10
90
11
89
Dowex 1x8 powder Pierce polystyrene Anoxic Yes 1.8 100 48 52 47 53

a. 1 mL of uranium solution added to resin, uncertainty in recovered Utot was 3%.