Skip to main content
. 2013 Jan 21;14(1):2011–2021. doi: 10.3390/ijms14012011

Table 3.

Rate constants (kobs) for substrates IIV. Only the pseudo-first order rate constants are reported, since all studies were performed at a constant concentration of A.

substrate background (×10−3·s−1) catalyst A (×10−3·s−1) Au MPC 1 (×10−3·s−1) Au MPC 1•A (×10−3·s−1) Au MPC 1•WDDD (×10−3·s−1) Ratio a
I 0.05 0.05 1.0 8.9 0.3 30
II 0.01 0.03 0.9 7.2 0.4 18
IIIL 0.05 0.04 0.2 2.0 0.1 20
IIID 0.05 0.04 0.2 2.0 0.1 20
IV 2.5 2.5 5.5 4.2 2.5 1.7
V 0.01 - 0.01 0.1 0.01 10b
VI 0.01 0.01 0.01 0.2 0.01 20b
a

The ratio refers to the observed rate acceleration between the catalytic system Au MPC 1A and Au MPC 1•WDDD (i.e., columns 5 and 6, respectively);

b

This ratio is mainly determined by the very low rate constant determined for Au MPC 1•WDDD.