Wastewater characteristics at the WWTPs studied at the time of sampling

Treatment plant Source Value for wastewater characteristica
Temp (°C) pH Turbidity (NTU) SS (mg/liter) COD (mg/liter) Mean particle size (μm) E. coli count (CFU/100 ml)
Activated sludge
    AS1 Influent 13.0 7.2 80.0 163 434 10.4 4 × 106
Effluent 13.8 7.2 20.0 20.5 73.4 18.4 3 × 105
    AS2 Influent 9.9 7.2 62.5 181 306 10.9 5 × 106
Effluent 10.0 7.7 9.5 11.0 46.3 13.4 5 × 104
Physicochemical
    PC1 Influent 13.0 7.6 39.5 96.0 131 11.4 2 × 106
Effluent 13.1 7.2 7.22 8.77 38.5 7.6 1 × 105
    PC2 Influent 16.7 7.8 30.5 27.3 80.6 5.4 2 × 106
Effluent 16.0 7.4 9.5 12.0 34.9 7.1 8 × 105
a

SS, suspended solids; COD, chemical oxygen demand; NTU, nephelometric turbidity units.