Table 1.
Propagated errors in free energy at different levels of truncation at the isoenergetic point for small microstate energy errors.
1st order | 2nd order | 4th order | MC results | |
---|---|---|---|---|
Systematic Error | 0 | −0.420 | −0.272 | −0.293 |
Random Error | 0.707 | 0.569 | 0.653 | 0.780 |