Skip to main content
. Author manuscript; available in PMC: 2014 Mar 15.
Published in final edited form as: Toxicon. 2013 Jan 10;64:43–54. doi: 10.1016/j.toxicon.2012.12.025

Table 1.

Sonoclot analysis of whole blood platelet function on clot retraction by r-Cam-dis and r-mojastin-1.

Sample Platelet functiona Mean ± SD (n=3) P value
Controlb 2.63 ± 0.31 -
r-Cam-dis (0.3 μg/mL) 2.63 ± 0.38 1.00
r-Cam-dis (1 μg/mL) 0.23 ± 0.15 0.0003
r-Cam-dis (6 μg/mL) 0.17 ± 0.06 0.0002
r-Mojastin-1 (29 μg/mL)c 3.00 ± 0.44 0.30
Cleaved Nus tag 2.90 ± 0.89 0.65

Bold letter indicates the significant reduction of the platelet function by r-Cam-dis compared with the control at P < 0.05.

a

Platelet function is defined as the function of clot retraction. A platelet function greater than 1 represents normal clot retraction. A platelet function of less than 1 represents no clot retraction.

b

The control was citrated blood that was activated with glass beads contained in the cuvette and 0.3 M CaCl2.

c

r-Mojastin-1 at a final concentration of 29 μg/mL (4 μM) was used for comparison.