Microleakage values (mm) obtained in the study.

Group No Test Material Surface Coating Median IQR Minimum Maximum
1 GIC 0,50a 0,38 0,00 1,00
2 GIC + 0,35b 0,45 0,00 1,00
3 GC 1,00c 0,40 0,30 1,00
4 GC + 0,25b 0,78 0,00 1,00
5 COMP 0,20b 0,60 0,00 1,00

Values with same superscript letters are not significantly different at P=.05 (Conover’s Multiple Comparisons test).

GIC: Glass ionomer cement; GC: Glass carbomer; COMP: Compomer; IQR: Interquartile range.