Table 4.

RMS error (microvolt) in the time domain between the three pairs of textile electrode Type I and standard electrodes using gel and NaCl, respectively (standard electrodes are denoted with an “a” after the channel name). To the right the grand average is given.

F3-F3a C3-C3a P3-P3a Mean

gel NaCl gel NaCl gel NaCl gel NaCl
Mean 4.33 2.57 5.77 4.38 5.43 3.38 5.18 3.44
Min 3.07 0.77 2.27 3.21 1.72 0.96
Max 5.49 4.26 11.8 5.59 9.24 6.69