Skip to main content
. 2013 Jan 28;40(2):021715. doi: 10.1118/1.4788653

Figure 6.

Figure 6

Comparisons of ROCO vs Clinical IMRT plan results for the H&N critical constraints: (a) Cord Dmax, (b) Brainstem Dmax, and (c) Chiasm Dmax. (d) Comparison of ROCO vs Clinical IMRT plan PTV D95 for the 100% prescription dose level.