Skip to main content
. 2012 Oct 30;15(3):277–283. doi: 10.1093/eurjhf/hfs173

Table 3.

The haemodynamic profile of the patient cohort assessed by right heart catheterization

Measure Control (SD) PAH (SD) P-value
HR (b.p.m.) 69.2 (23.6) 77.6 (16.9) 0.36
MAP (mmHg) 96.8 (8.3) 96.2 (15.3) 0.93
RAP (mmHg) 8.0 (4.2) 12.7 (7.7) 0.2
PASP (mmHg) 30.9 (5.1) 69.5 (15.5) <0.0001
PADP (mmHg) 13.8 (7.1) 29.5 (9.4) <0.002
mPAP (mmHg) 21.4 (5.0) 45.5 (10.4) <0.0001
PCWP 12.4 (6.0) 12.8 (6.2) 0.91
CO (L/min) 6.4 (0.8) 5.1 (1.5) 0.09
CI (L/min/m2) 3.4 (0.4) 2.7 (0.6) 0.06
PVR (Wood units) 1.41 (0.6) 7.3 (3.8) <0.003
SVR (dyn/s/cm5) 1123.9 (196.1) 1439.3 (570.9) 0.24

CI, cardiac index; CO, cardiac output; HR, heart rate; MAP, mean arterial pressure; mPAP, mean pulmonary arterial pressure; PADP, pulmonary artery diastolic pressure; PAH, pulmonary arterial hypertension; PASP, pulmonary artery systolic pressure; PCWP, mean pulmonary capillary wedge pressure; PVR, pulmonary vascular resistance; RAP, right atrial pressure; SVR, systemic vascular resistance.