Skip to main content
. 2013 Feb 20;8(2):e55861. doi: 10.1371/journal.pone.0055861

Table 1. Tmax (tension at pCa 4.5); calcium sensitivity (pCa50) and Hill coefficient (nH) of WT and KO in 0, 5, and 10 µM CK-2066260.

Genotype/parameter CK-2066260 concentration
0 µM 5 µM 10 µM
WT- Tmax (mN/mm2) 46.6±5.5 49.7±5.1 47.8±6.0
KO- Tmax (mN/mm2) 19.9±4.0** 22.1±4.1** 22.2±4.5**
WT- pCa50 5.85±0.04 6.18±0.04# # 6.30±0.04# #√√
Δ from 0 CK (pCa unit) 0.34±0.02 0.45±0.02√√
KO- pCa50 5.98±0.03* 6.29±0.01* # # 6.43±0.05# #√√
Δ from 0 CK(pCa unit) 0.31±0.02 0.45±0.04√
WT- nH 2.64±0.07 3.21±0.20 3.29±0.34
KO- nH 2.83±0.15 3.14±0.38 2.16±0.58
WT- Tmax (SL 2.6 µm) 58.7±6.0 NA 66.7±6.4#
KO- Tmax (SL 2.6 µm) 34.0±5.7** NA 44.5±8.0**# #
WT- nH (SL 2.6 µm) 2.7±0.28 NA 2.31±0.24
KO- nH (SL 2.6 µm) 3.09±0.11 NA 1.47±0.24*# #

Results are mean ± SEM from 5 WT and 5 KO mice, except for the last 4 rows that are from 6 WT and 6 KO mice.

*

comparison WT vs. KO;

#

comparison versus 0 µM CK-2066260;

comparison versus 5 µM CK-2066260; single symbol p<0.05, double symbol p<0.01. All measurements were at a sarcomere length (SL) of 2.1 µm, except the bottom 4 rows that were at 2.6 µm.