Skip to main content
. 2013 Jan 2;288(8):5572–5580. doi: 10.1074/jbc.M112.436410

TABLE 2.

hPol δ catalysis of nucleotide addition during correct and incorrect incorporation

Primer extension experiments measured incorporation of dCTP or dTTP across from template G. S.D. reflect three replicate experiments.

Pol δD400A Pol δDQ Fold (DQ:D400A)
Correct (dCTP-G)a
    Vmax (fmol/min) 18 ± 0.13 26 ± 1.2
    Kmm) 0.25 ± 0.01 2.5 ± 0.4
    kcat (min−1) 0.51 ± 0.004 0.19 ± 0.009
    kcat/Km 2 0.076 −26

Incorrect (dTTP-G)b
    Vmax (fmol/min) 38 ± 11 9.1 ± 0.98
    Kmm) 340 ± 180 180 ± 43
    kcat (min−1) 0.39 ± 0.11 0.027 ± 0.002
    kcat/Km 0.001 0.0001 −10
    finc*c 0.0005 0.0013 2.6

a Correct incorporation experiments used 0.14 pmol hPol δDQ and 0.036 pmol hPol δD400A.

b Incorrect incorporation experiments used 0.336 pmol hPol δDQ and 0.099 pmol hPol δD400A.

c finc given by (kcat/Km)incorrect/(kcat/Km)correct.