Skip to main content
. 2013 Feb 7;14(1):464–474. doi: 10.1208/s12249-013-9931-7

Table II.

Dissolution Endpoints (T end) Measured by DSC for STZ/Soluplus®, SDM/Soluplus®, SMZ/Soluplus® and SDZ/Soluplus® Systems

X Soluplus® T end (°C) STZ/Soluplus® T end (°C) SDM/Soluplus® T end (°C) SMZ/Soluplus® T end (°C) SDZ/Soluplus®
0.0 202.5 ± 0.4 198.9 ± 0.1 237.5 ± 0.1 252.7 ± 0.1
0.1 200.7 ± 0.1 197.8 ± 0.2 233.8 ± 0.1 247.2 ± 0.4
0.2 200.0 ± 0.1 196.2 ± 0.0 231.9 ± 0.1 244.0 ± 0.1
0.3 195.8 ± 0.0 193.6 ± 0.0 230.2 ± 0.1 242.0 ± 0.1
0.4 191.4 ± 0.1 189.7 ± 0.0 228.2 ± 0.1 240.0 ± 0.0
0.5 183.8 ± 0.0 183.7 ± 0.0 224.2 ± 0.0 237.7 ± 0.0
0.6 170.1 ± 0.0 173.8 ± 0.0 214.6 ± 0.2 234.1 ± 0.1
0.7 165.4 ± 0.4 201.8 ± 0.6 227.1 ± 0.0

X Soluplus® weight fraction of Soluplus®

Each value is the average of two measurements. The value after ± is the standard deviation