Skip to main content
. Author manuscript; available in PMC: 2013 Mar 2.
Published in final edited form as: J Cancer Sci Ther. 2013;5(2):052–057. doi: 10.4172/1948-5956.1000184

Table 2.

Strain and M-mode echocardiography parameters for ventricular function [mean (standard deviation)] obtained from Wistar rats by the end of the experimental period.

Groups
Parameters Control Doxorubicin Doxorubicin +
stem cells
Doxorubicin +
C. sinensis
Radial Strain
Velocity (cm/s) 1.95(0.4) 1.02(0.4)* 1.94(0.6) 1.08(0.2)*
Displacement (mm) 0.90(0.2) 0.49(0.2)* 0.80(0.2) 0.51(0.2)*
Strain (%) 21.7(2.8) 13.0(7.3) 33.3(25.4) 11.0(4.2)
Strain rate (1/s) 5.7(0.5) 3.9(0.5) 5.9(2.3) 3.7(0.3)
M-mode
Ejection fraction (%) 70.7(3.9) 60.8(13.0) 73.6(1.9) 63.6(4.1)
Fractional shortening (%) 41.6(2.7) 33.4(9.2) 43.6(1.6) 35.2(3.5)
*

p < 0.05 vs. Control;

p < 0.05 vs. Doxorubicin