Table 1.

Table Hemodynamic Parameters at Baseline, After the Setting of the Stenosis, and During Vasodilator Stress at 123I-ZIROT Injection

Parameters Rest
Stress
Baseline Stenosis
HR, BPM 123±15 121±13 135±19
MAP, mm Hg 102±7 99±6 80±8*
LAP, mm Hg 5±1 6±2 6±2
LVP, mm Hg 119±8 113±8* 102±10*
LVEDP, mm Hg 6±2 7±2 6±2
dP/dt, mm Hg/s 2030±313 1779±148 2489±342

Data are given as mean±SEM. n=5. BPM indicates beats/minute; dP/dt, first derivative of LVP with respect to time; HR, heart rate; LAP, left atrial pressure; LVP, left ventricular pressure; LVEDP, left ventricular end-diastolic pressure; MAP, mean arterial pressure.

*

P<0.05 vs baseline.

P<0.05 vs stenosis.