Table 2.
| |||||
---|---|---|---|---|---|
Entry | Substratea | Conditionsb |
RCY (%)c |
||
Temp (°C) |
Time (s)d |
Ar18F | Ar’18F | ||
1 | 13 | 130 | 224 | 1a, 64 (56) | 10a 0 (0) |
2 | 14 | 120 | 236 | 1a, 93 (89) | 2a, <1 (<1) |
3 | 15 | 150 | 314 | 1a, 76 (68) | 4a, 0 (0) |
4 | 16 | 200 | 236 | 16a, 73 (55) | 10a 0 (0) |
5 | 17 | 140 | 314 | 17a, 46 (32) | 1a, 43 (25) |
6 | 18 | 200 | 236 | 18a, 61 (43) | 10a 0 (0) |
7 | 19 | 140 | 236 | 19a, 36 (20) | 1a, 45 (35) |
8 | 20 | 200 | 236 | 20a 0 (0) | 10a 0 (0) |
5 mM in DMF.
Conditions giving highest RCYs among 8−12 different runs, except for entry 8 where the most extreme tested condition is given.
RCYs are those determined with HPLC. RCYs given in parentheses are with correction for radioactivity adsorption in the apparatus.
Estimated residence time in the micro-reactor.