Skip to main content
. 2012 Nov 7;54(2):383–397. doi: 10.1093/jrr/rrs100

Table 4.

Effective dose per unit fluence (pSv cm2) under ISO irradiation of proton energy on phantoms

Energy(MeV) Effective dose per unit fluence (pSv cm2)
VCH-FA VCH-male MIRD-female ICRP-female
5 0.45 0.65 0.97 1.26
10 19 24 23 32
14 39 52 46 59
20 50 180 119 110
30 60 425 235 193
50 240 605 364 405
75 748 930 683 777
100 1373 1300 1078 1247
150 2112 1993 1816 2005
200 1971 1834 1819 1977
300 1475 1474 1385 1501
500 1214 1148 1127 1222
1000 1138 1078 1062 1160
2000 1149 1082 1069 1153
5000 1291 1231 1212 1314
10000 1517 1439 1414 1535