Table 1. Primary antibodies used for ICC and WB.
Antigen (Clone) | Immunogen | Species | Isotype, clonality* | Brand | Dilution for ICC (WB) |
---|---|---|---|---|---|
Acetylated α-tubulin (6-11B-1) | Outer arm of Strongylocentrotus purpuratus | Mouse | IgG2b, monoclonal | Sigma–Aldrich® | 1:1000 |
Activated caspase III | Peptide RGTELDCGIETD of human activated caspase III with added KLH amino acids | Rabbit | Monoclonal† | Cell Signaling Technologies | 1:100 |
BrdU (BMC 9318) | BrdU conjugated to BSA | Mouse | IgG1, monoclonal | Roche | 1:100 |
GFAP | Amino acids 1–428 of GFAP from bovine spinal cord | Chicken | IgY, polyclonal | Neuromics | 1:500 |
GFAP-Cy3 (G-A-5) | GFAP from pig spinal cord | Mouse | IgG1, monoclonal | Sigma–Aldrich® | 1:1000 |
Human Tf | Human seric Tf synthetic peptide | Chicken | IgY, polyclonal | GeneTex | 1:100 |
MBP | Amino acids 1 to 154 from rat MBP N-terminal fragment | Rabbit | Polyclonal | Dr A. Campagnoni Lab (UCLA, USA) | 1:500 |
Mouse Tf (I-20) | N-terminal peptide of mouse Tf | Mouse | Polyclonal | Santa Cruz Biotechnologies | 1:50 |
Nestin | Peptide containing peptide sequence shared between human and rat Nestin | Chicken | Polyclonal | Neuromics | 1:100 |
NG2 | NG2 proteoglycan chondrotin sulfate purified from rat | Rabbit | IgG, polyclonal | Millipore | 1:200 |
Olig2 (211F1.1) | Human recombinant Olig2 | Mouse | IgG2a, k, monoclonal | Millipore | 1:100 |
PDGFRα | Mouse recombinant PDGFRα | Goat | Polyclonal | Neuromics | 1:100 |
Rat Tf | Unknown | Rabbit | Polyclonal | Dr. Zakin laboratory (Institute Pasteur, France) | 1:100 (1:2500) |
Sox2 | Synthetic peptide sequence containing amino acids 300 to C-terminal end of human Sox2 with added KLH amino acids | Rabbit | IgG, Polyclonal | Abcam | 1:100 |
TfRc1 or CD71 (42/6) | Human purified TfRc1 | Mouse | IgA, monoclonal | Millipore | 1:20 |
TfRc1 or CD71 (OX-26) | Phytohemagglutinine-activated lymph node cells | Mouse | IgG2a,k, monoclonal | BD Pharmingen™ | 1:50 |
*The polyclonal antibodies with no assigned isotype indicate they contained more than one isotype or the isotype was not specified by the manufacturer.
†We did not have access to data regarding the antibody isotype.