Table 2. Changes of the intraventricular pressure, mean arterial pressure, and pulse rate due to bilateral common jugular venous clipping.
Time point | IVP (mmHg) | p-value | MAP (mmHg) | p-value | PR (beats/min) | p-value |
Before | 6.9±3.1 | 97.2±11.2 | 392.3±57.1 | |||
During | 9.2±3.5 | 0.008 | 90.0±10.2 | 0.008 | 395.1±48.8 | 0.678 |
<30sec After | 6.8±3.0 | 0.110 | 96.3±10.2 | 0.441 | 393.0±50.7 | 0.859 |
>30sec After | 7.4±3.4 | 0.767 | 97.0±8.7 | 0.953 | 377.0±42.1 | 0.260 |
(n = 9).
<30 sec After: less than 30 seconds after bilateral common jugular venous clipping.
>30 sec After: more than 30 seconds after bilateral common jugular venous clipping.
Abbreviations: IVP, intraventricular pressure; MAP, mean arterial pressure; PR, pulse rate. For p-values, comparison is to the initial time point (before bilateral common jugular venous clipping).