Skip to main content
. 2012 Jul 8;13(1):36–42. doi: 10.1007/s13191-012-0140-y

Table 3.

Mean values obtained from three gingival retraction systems with relation to time taken, vertical retraction and horizontal retraction

Parameters/retraction systems N Mean SD Minimum Maximum
Time taken
 Stay-put 20 215.1 s 37.44 s 135 s 285 s
 Expasyl 20 75.15 s 17.95 s 45 s 110 s
 Magic foam cord 20 79.75 s 18.36 s 45 s 112 s
Vertical Retraction
 Stay-put 20 1.0655 mm 0.3851 mm 0.42 mm 2.17 mm
 Expasyl 20 0.484 mm 0.195 mm 0.17 mm 1 mm
 Magic foam cord 20 0.8645 mm 0.3029 mm 0.33 mm 1.42 mm
Horizontal Retraction
 Stay-put 20 0.233 mm 0.082 mm 0.15 mm 0.40 mm
 Expasyl 20 0.151 mm 0.069 mm 0.05 mm 0.29 mm
 Magic foam cord 20 0.199 mm 0.085 mm 0.03 mm 0.35 mm

N number of abutments, SD standard deviation, s seconds, mm millimeters