Skip to main content
. 2013 Mar 2;13:30. doi: 10.1186/1472-6947-13-30

Table 6.

Sensitivity and specificity of various classifiers trained on the acute renal failure data set for difference percentages of over-sampling

Over-sampling
SVM
MyC
RIPPER
C4.5
Imbalance
(%) Sens. Spec. Sens. Spec. Sens. Spec. Sens. Spec. ratio
0
0.62
0.92
0.69
0.90
0.75
0.89
0.69
0.88
16
100
0.66
0.86
0.78
0.80
0.81
0.76
0.74
0.75
8
200
0.71
0.81
0.84
0.71
0.84
0.65
0.77
0.67
5
300
0.74
0.77
0.89
0.59
0.88
0.65
0.80
0.65
4
400
0.76
0.73
0.89
0.51
0.86
0.64
0.81
0.61
3
500
0.77
0.69
0.89
0.48
0.84
0.64
0.82
0.60
3
600
0.78
0.66
0.91
0.48
0.89
0.59
0.82
0.60
2
700
0.82
0.60
0.92
0.43
0.89
0.54
0.82
0.60
2
800
0.82
0.57
0.94
0.37
0.86
0.60
0.82
0.61
2
900
0.83
0.55
0.93
0.36
0.89
0.53
0.83
0.61
2