Skip to main content
. 2013 Mar 2;13:30. doi: 10.1186/1472-6947-13-30

Table 8.

Sensitivity and specificity of various classifiers trained on the acute renal failure data set for difference cost values of cost-sensitive learning

 
SVM
MyC
RIPPER
C4.5
Cost Sens. Spec. Sens. Spec. Sens. Spec. Sens. Spec.
1
0.59
0.92
0.74
0.85
0.78
0.80
0.67
0.73
10
0.59
0.92
0.81
0.63
0.78
0.80
0.73
0.69
25
0.59
0.92
0.81
0.63
0.78
0.80
0.76
0.64
50
0.59
0.92
0.89
0.35
0.78
0.80
0.78
0.60
100
0.59
0.92
1.00
0.00
0.78
0.80
0.97
0.11
200
0.59
0.92
1.00
0.00
1.00
0.00
1.00
0.00
400
0.59
0.92
1.00
0.00
1.00
0.00
1.00
0.00
800
0.59
0.92
1.00
0.00
1.00
0.00
1.00
0.00
1000 0.59 0.92 1.00 0.00 1.00 0.00 1.00 0.00