Results of sensitivity/specificity analysis for RCM parameters are shown. Table presents ranking in order of 1) highest sensitivity 2) highest specificity, from scoring of investigator 1 (INV I). Only data with relevant reproducibility have been included in the analysis. Data are expressed as % of all examined cases. A p-value 0.05 was considered significant (Pearson Chi2 Test).

RCM parameter SpecInv I SensInv I p-value Inv I Spec Inv II Sens- Inv II p-value Inv II
Spongiosis 88.9% 94.7% 0.0001 77.8 100 0.0001
Loss of demarcation 88.9% 94.7% 0.0001 77.8 94.7 0.0001
Disarray of epidermis 77.8% 89.5% 0.0001 77.8 100 0.0001
Hyporefractile rings 88.9% 78.9% 0.001 100 84.2 0.0001
Junctional atypical lymphocytes 100% 73.7% 0.0001 100 84.2 0.0001
Vesicle-like structures (Pautrier’s microabcesses) 100% 73.7% 0.0001 88.9 52.6 0.036
Epidermal atypical lymphocytes 100% 73.7% 0.0001 100 68.4 0.001
Blood vessel dilatation 77.8% 57.9% 0.077 100 78.9 0.0001
Dendritic cells 100% 52.6% 0.007 100 36.8 0.035