Skip to main content
. 2013 Apr 15;70:377–385. doi: 10.1016/j.neuroimage.2012.12.058

Table 1.

The 3D-affine registration corrects for rigid-body subject motion and 3D eddy currents (see Mohammadi et al., 2010). The slice-wise registration was preceded by a rigid-body registration to reduce 3D shifts in the x- and y-direction, and 3D scaling in the y-direction.

Registration method Translation Rotation Scaling Shearing Number of parameters
3D-affine x-, y-, and z- direction x-, y-, and z- axis x- and y- direction x-y plane and z-y plane 9
Rigid-body x- and y-direction None y-direction None 3
Slice-wise x- and y-direction None y-direction None 24a
a

Due to poor data quality and edge effects, the first and last slices were not included in the slice-wise registration method, yielding 8 × 3 parameters.