Table 5.

Voxel similarity measured using the Dice Similarity Coefficient (DSC) and associated interquartile range (IQR) between manual and SBHV automatic bilateral hippocampal labels for the Sunnybrook automated pipeline leave-one-out optimization dataset (template n=30), and Sunnybrook LOOCV dataset (template n=70). Values reported are based on the automated labels that were generated by nonlinear registration to the target space and label fusion of the 15 best matching MRI templates. P1= (Haller et al., 1997), P2=(Killiany et al., 1993), P3=(Malykhin et al., 2007), P4=(Pruessner et al., 2000) and P5=(Pantel et al., 2000).



Atlas
Protocol
Median DSC IQR ICC 95% CI
Sunnybrook Optimization Experiment

P1 0.87 0.05 0.93 (0.56 – 0.98)
P2 0.85 0.04 0.86 (0.42 – 0.96)
P3 0.89 0.03 0.94 (0.79 – 0.98)
P4 0.88 0.03 0.94 (0.60 – 0.98)
P5 0.89 0.03 0.93 (0.76 – 0.98)
Sunnybrook LOOCV Experiment
P1 0.86 0.04 0.92 (0.72 – 0.96)
P2 0.85 0.04 0.88 (0.40 – 0.96)
P3 0.88 0.02 0.94 (0.80 – 0.99)
P4 0.88 0.03 0.91 (0.54 – 0.97)
P5 0.88 0.02 0.93 (0.72 – 0.97)