Skip to main content
. Author manuscript; available in PMC: 2013 Nov 1.
Published in final edited form as: Osteoarthritis Cartilage. 2012 Aug 10;20(11):1286–1293. doi: 10.1016/j.joca.2012.08.003

Table 3.

Adjusted odds ratios with 95% confidence intervals, p-values and sample sizes for each biomarker by lumbar disc space narrowing and anterior vertebral osteophytes.

Disc Space Narrowing Osteophytes
Biomarker (unit of measure) Adjusted OR (95%CI) p-value Adjusted OR (95% CI) p-value
lnCTX-II* (ng/mM Cr) 1.49 (1.15, 1.92) <0.01 1.33 (1.02, 1.72) 0.03
lnNTX-I (nMBCE/mMCr) 1.27 (1.01, 1.60) 0.04 0.82 (0.65, 1.05) 0.11
lnCP-II* (ng/ml) 1.68 (1.09, 2.61) 0.02 0.88 (0.56, 1.38) 0.58
lnC2C* (ng/ml) 1.77 (0.96, 3.24) 0.07 1.10 (0.60, 2.00) 0.76
lnCOMP* (ng/ml) 1.18 (0.76, 1.81) 0.46 1.08 (0.70, 1.67) 0.73
lnHA* (ng/ml) 1.21 (1.01, 1.45) 0.04 1.09 (0.91, 1.31) 0.34

C-terminal crosslinked telopeptide (CTX-II) measured in nanogram per millimole, accounting for creatinine clearance. Cross-linked N-telopeptides (NTX-I) measured in nanomole of bone equivalents accounting for creatinine clearance. C-Propeptide (CP-II), Cleavage of type II collagen (C2C), Cartilage oligomeric matrix protein (COMP) and Hyaluronic Acid (HA) all measured in nanograms per milliliter. OR=odds ratio. CI=confidence interval. All models adjusted for age, race, gender, BMI and the other outcome.

*

adjusted for knee OA.