Skip to main content
. Author manuscript; available in PMC: 2013 Nov 1.
Published in final edited form as: J Microbiol Methods. 2012 Sep 4;91(2):231–239. doi: 10.1016/j.mimet.2012.08.016

Table 2.

Variability in fluorescence intensity due to size of area and location where dust sample is collected.

Adjacent Area Same Size 1×1 vs. 1×1m2 Adjacent Area Different Sizes 1×1 vs. 2×2m2 Location Bed, BRa Floor, LRb Floor
Variance* 0.0073 0.0093 0.0125
95% Confidence Intervalc 0.0072 to 0.0075 0.0091 to 0.0094 0.0124 to 0.0126
% of Total Variabilityd 3.6% 4.5% 6.1%
a

BR, bedroom

b

LR, TV/Living room

*

Residual variance component estimate in the linear mixed effects model after accounting for taxa-to-taxa variability, home-to-home variability, and their interaction.

c

95% percentile confidence intervals based on 5000 parametric bootstrap samples

d

(Residual variance / Total variance) × 100%