Published in final edited form as: Phys Med Biol. 2013 Feb 15;58(5):1563–1579. doi: 10.1088/0031-9155/58/5/1563

Table 3.

Quantitative results for the in vivo reconstructions using simulated and experimental data. Cases #6-8 represent experimental data where the target location is estimated by clock position and tentative (x,y,z) values are given to roughly mimic the coordinates of the clock positions relative to the breast geometry.

# Data Type Actual Target
Location (x,y,z) cm
Actual
Target
Volum
e (cm3)
Actual
T:B
Recovered Target
Location (x,y,z)
cm
Recovered
Target
Volume
(cm3)
Recovere
d T:B
Total
Dista
nce
Off
(cm)
1 Simulated (2.5, 0, 0) 0.45 1:0 (1.05, 0, -0.66) 1.11 240:1 1.59
2 Simulated (2.5, -4, -1) 0.45 1:0 (2.33, -4.48, -1.16) 0.68 120:1 0.53
3 Simulated (2.5, 2.5, -1) 0.23 1:0 (2.21, 2.19, -1.02) 0.72 190:1 0.43
4 Simulated (2.5, 0, 0) 0.45 100:1 (1.18, -0.02, -0.68) 1.00 6:1 1.49
5 Simulated (2.5, 0, 0) 0.45 50:1 (1.18, 0.08, -0.84) 0.63 1:1 1.57
6 Experimental ~ 6o’clock 0.45 1:0 (1.25, -1.14, -1.21) 0.92 78:1 N/A
7 Experimental ~ 4 o’clock 0.45 1:0 (2.97, -5.40, -0.68) 0.36 7:1 N/A
8 Experimental ~ 8 o’clock 0.23 1:0 (0.87, -1.56, -1.82) 0.12 16:1 N/A