Skip to main content
. 2013 May;61(8):2973–2983. doi: 10.1016/j.actamat.2013.01.057

Table 3.

Summary of the fracture experiments for the different specimen orientation using a LEFM approach.

Orientation Pmax/PQa KQ (MPa m1/2) KIC (MPa m1/2)
A 1 21.6 21.6
1 26.3 26.3
1 20.5 20.5



B 1.86 50.2
1.39 59.1
1.23 75.4



C 1.51 48.5
1.52 46.7
1.75 46.3
a

Pmax/PQ is the ratio of maximal force, Pmax, and the calculated value, PQ, using the 5% secant deviation procedure according to ASTM E-399.