Skip to main content
. 2012 May 8;27(7):1994–2000. doi: 10.1093/humrep/des140

Table I.

Studies included in review of the efficacy of IUDs for emergency contraception over 35 years, in order of publication.

Study Country IUD type Max. time to insertion (days) Enrolled (n) Efficacy population (n) Pregnancies (n) Pregnancy rate (%) (95% CI)a
Gottardi et al. (1979)b Italy Cu T-200 2 60 60 0 0 (0–6.0)
Lippes et al. (1979)b USA Cu T-200, Cu 7 7 299 299 0 0 (0–1.2)
Tyrer (1980)b USA Cu 7 5 80 80 0 0 (0–4.5)
Black et al. (1980)b UK Cu 7, Lippes Loop D 10 191 176 0 0 (0–2.1)
Van Santen and Haspels (1981)b Netherlands MLCu-250, Cu 7, Cu T-200 5 55 55 0 0 (0–6.5)
Goldstuck (1983)b UK Cu 7, Cu 7 Mini, Cu T, MLCu 250, MLCu 250 short 10+ 71 64 0 0 (0–5.6)
Guillebaud et al. (1983)b UK Cu 7, Lippes Loop 5 87 87 0 0 (0–4.2)
Gottardi et al. (1986)b Italy Cu T-200, Cu 7, Cu 7 Mini, MLCu-250 7 98 91 0 0 (0–4.0)
Luerti et al. (1986)b Italy MLCu-250, Cu 7, Cu T 7 117 102 0 0 (0–3.6)
Askalani et al. (1987)b Egypt Cu T-200 4 200 200 4 2.0 (0.5–5.0)
Yang et al. (1997) China ML Cu-375 SL 5 30 30 0 0 (0–11.6)
Li et al. (1999) China ML Cu-375 SL 5 101 101 0 0 (0–3.6)
Zhang et al. (1999) China ML Cu-375 SL 5 100 100 0 0 (0–3.6)
Lu (2000) China Copper IUD (unspecified) 5 28 28 0 0 (0–12.3)
Tian (2000) China Copper IUD (unspecified) 5 80 80 0 0 (0–4.5)
Li et al. (2001) China Cu T-380A 5 94 94 0 0 (0–3.8)
Zhao et al. (2001) China ML Cu-375 SL 5 98 98 1 1.0 (0.0–5.6)
Zhou and Xiao (2001)b China ML Cu-375 SL 5+ 1013 998 1 0.1 (0.0–0.6)
Liu and Chen (2002a,b) China ML Cu-375 SL 5 80 80 1 1.2 (0.0–6.8)
Liu and Chen (2002a,b) China Copper IUD (unspecified) 3 95 95 0 0 (0–3.8)
Sun et al. (2003) China GyneFix 5 86 86 0 0 (0–4.2)
D'Souza et al. (2003)b UK GyneFix, Gyne-T 380S Unspecified 173 169 0 0 (0–2.2)
Tang et al. (2003) China ML Cu-375 SL 5 98 98 1 1.0 (0.0–5.6)
Wang and Jiang (2003) China Copper IUD (unspecified) 5 86 86 0 0 (0–4.2)
Zhao and Wang (2004) China Cu T-220 5 108 108 0 0 (0–3.4)
Hou (2005) China Nova T-380 5 100 100 0 0 (0–3.6)
Li et al. (2005) China ML Cu-375 SL 5 150 150 0 0 (0–2.4)
Wen (2005) China Cu T-380A 5 218 218 1 0.5 (0.0–2.5)
Wang et al. (2006) China Cu T-380A 5 200 200 0 0 (0–1.8)
Dong and Wu (2007) China Copper IUD (unspecified) 5 87 87 0 0 (0–4.2)
Sheng and Zhang (2007) China Copper IUD (unspecified) 5 27 27 0 0 (0–12.8)
Song et al. (2007) China ML Cu-375 SL 5 180 180 0 0 (0–2.0)
Yang et al. (2008) China Cu T-380A 5 100 100 0 0 (0–3.6)
Hong (2008) China GyneFix 5 100 100 0 0 (0–3.6)
Ma et al. (2008) China MCu 5 26 26 0 0 (0–13.2)
Yang et al. (2008) China ML Cu-375 SL 5 86 86 0 0 (0–4.2)
He (2009) China Copper IUD (unspecified), ML Cu-375 SL 5 108 108 0 0 (0–3.3)
Hong (2009) China Copper IUD (unspecified) 5 70 70 0 0 (0–5.1)
Liu et al. (2010) China ML Cu-375 SL 5 162 162 1 0.6 (0.0–3.4)
Turok et al. (2010)b USA Cu T-380A 5 23 22 0 0 (0–15.4)
Wang (2010) China Copper IUD (unspecified) 5 40 40 0 0 (0–8.8)
Wu et al. (2010)b China Cu T-380A 5 1963 1893 0 0 (0–0.2)

aWhere the pregnancy rate is zero, a one-sided 97.5% CI is calculated. Otherwise, a 95% exact binomial CI is calculated.

bIndicates publication in English; otherwise, studies were published in Chinese.

HHS Vulnerability Disclosure