Skip to main content
. 2013 Mar 11;14(1):23. doi: 10.1186/1129-2377-14-23

Table 1.

This table shows the results of the electrophysiological study: Pattern Reversal-VEP initial amplitudes (N1P1 and P1N2, μV), and habituation slopes in healthy volunteers (HV) and episodic migraineurs (MoA), before, just after and 3 h after anodal tDCS

Groups and VEP comparison
First block amplitude (μV)
Habituation slope (over six blocks)
  Before After + 3h Before After + 3h
Healthy volunteers
 
 
 
 
 
 
(n=11)
 
 
 
 
 
 
N1P1
6.1±2.0
6.8±2.6
6.3±2.2
-0.07±0.14
-0.21±0.14*
-0.08±0.14
P1N2
6.6±2.1
6.5±2.0
6.0±1.6
-0.18±0.19
-0.14±0.16
-0.12±0.25
Episodic migraineurs
 
 
 
 
 
 
(n=13)
 
 
 
 
 
 
N1P1
7.1±2.9
7.3±3.1
7.2±2.7
-0.10±0.11
-0.24±0.18*
-0.11±0.17
P1N2 6.6±2.6 6.4±2.9 6.8±2.5 -0.01±0.21 -0.17±0.24 -0.07±0.21

The * mark corresponds to a significant change (p < 0.05).