Skip to main content
. 2012 Jun 1;1(6):125–130. doi: 10.1302/2046-3758.16.2000050

Table I.

Results of induction of bone around titanium implants with surfaces of porous coating (PC), porous coating with Bonemaster (PC+BM) and porous coating with plasma-sprayed hydroxyapatite (PC+HA) at six weeks, 12 weeks and combined for six and 12 weeks together

PC PC+BM PC+HA p-value*
Six weeks 2/6 1/6 0/6 0.27
12 weeks 3/6 0/6 0/6 0.049
Combined 5/12 1/12 0/12 0.01

* Fisher’s exact test