Skip to main content
. 2013 Jan 24;53(2):199–207. doi: 10.1007/s12088-013-0358-3

Table 5.

Carbon, nitrogen and selected inducer optimization

Run order Point type Experimental values Log10 CFU ml−1
Glucose (g L−1) Tween 80 (ml L−1) pH ± 0.2 Observed Predicted
1 Fact 25 (−1) 0.25 (0) 4.00 (−1) 5.99 6.57
2 Fact 35 (0) 0.00 (−1) 6.00 (+1) 0.00 1.18
3 Fact 35 (0) 0.00 (−1) 6.00 (+1) 6.03 5.94
4 Center 35 (0) 0.25 (0) 5.00 (0) 6.66 6.12
5 Fact 45 (+1) 0.50 (+1) 5.00 (0) 5.67 6.17
6 Fact 45 (+1) 0.00 (−1) 5.00 (0) 5.60 5.00
7 Fact 45 (+1) 0.25 (0) 4.00 (−1) 6.17 6.85
8 Fact 35 (0) 0.50 (+1) 4.00 (−1) 5.98 4.80
9 Fact 25 (−1) 0.25 (0) 6.00 (+1) 6.03 5.94
10 Fact 45 (+1) 0.25 (0) 6.00 (+1) 5.90 5.31
11 Fact 35 (0) 0.50 (+1) 6.00 (+1) 6.03 6.12
12 Fact 25 (−1) 0.50 (+1) 5.00 (0) 5.84 6.44
13 Center 35 (0) 0.25 (0) 5.00 (0) 5.82 6.12
14 Fact 25 (−1) 0.00 (−1) 5.00 (0) 4.31 3.81
15 Center 35 (0) 0.25 (0) 5.00 (0) 5.88 6.12

Box-Behnken. Experiments and results obtained from the response variable (Log10 CFU ml−1)

aThe observed values of Log10 CFU ml−1 were the mean values of triplicates. Highest values (results) in bold