Skip to main content
. 2013 Jan 9;109(7):1775–1781. doi: 10.1152/jn.00936.2012

Table 2.

Action potential and passive properties of control and septic rat motoneurons

Control Septic
Resting potential, mV −68.9 ± 3.0 −68.6 ± 2.0
Input resistance, MΩ 1.9 ± 0.3 1.8 ± 0.1
Rheobase current, nA 12.6 ± 2.3 12.9 ± 1.4
AP amplitude, mV 78.2 ± 4.7 76.7 ± 2.0
Rate of AP rise, mV/ms 405 ± 9 396 ± 6
AHP amplitude, mV 1.3 ± 0.4 1.5 ± 0.5
AHP half-decay time, ms 11.3 ± 1.5 11.6 ± 1.0

Values are means ± SE. Control, n = 6 motoneurons from 5 rats. Septic, n = 8 motoneurons from 4 rats. No differences were statistically significant. AP, action potential; AHP, afterhyperpolarization.