Skip to main content
. 2013 Apr 17;8(4):e61493. doi: 10.1371/journal.pone.0061493

Table 1. Separability indices for the connectivity matrices, Inline graphic.

Percentage p-value
Accuracy 84 0.0029
Specificity 80 0.0780
Sensitivity 88 0.0054
F-Score 84 0.0013

The fractions of correctly classified individuals were 8/9 for ASD and 8/10 for Control.