Strength of association between COR and ASSR measurements. Data from the left ear of the subjects at five COR frequencies (250 – 4000 Hz) and four ASSR frequencies (500 – 4000 Hz). The table shows the correlation value and below the corresponding probability.

COR 250 COR 500 COR 1000 COR 2000 COR 4000
ASSR 500 0.597 0.643 0.660 0.624 0.660
p-value 0.011* 0.003** 0.003** 0.008** 0.007**
ASSR 1000 0.504 0.591 0.652 0.617 0.504
p-value 0.007** 0.045* 0.017* 0.047* 0.130
ASSR 2000 0.497 0.684 0.696 0.620 0.812
p-value 0.198 0.056 0.052 0.119 0.010*
ASSR 4000 0.404 0.502 0.549 0.465 0.688
p-value 0.198 0.198 0.198 0.198 0.119
*

P < 0.05;

**

P < 0.01