Skip to main content
. 2013 Feb;33(1):29–35.

Table IV.

Correlation between COR and the presence of a TEOAE response. The r and l letters in the OAE column indicate responses from the right and left ear. Significant correlations are only presented for the right ear OAEs.

COR (Hz) OAE Correlation p-values
250 R 0.390 0.056
500 R 0.421 0.027*
1000 R 0.460 0.017*
2000 R 0.466 0.020*
4000 R 0.496 0.012*
250 L 0.361 0.056
500 L 0.344 0.095
1000 L 0.342 0.130
2000 L 0.347 0.130
4000 L 0.360 0.130
*

P < 0.05;