Skip to main content
. 2013 Apr 10;9:70. doi: 10.1186/1746-6148-9-70

Table 2.

Percentage of standardised synthetic cerumen (JSL) removed after each run (Test)

Test product
Weight removed (%)
 
Test 1
Test 2
Test 3
Mean of tests 1-3 Test 4*
  Mean ± SD Mean ± SD Mean ± SD Mean ± SD
Aurizon®
−42.7 ± 14.4
−29.8 ± 4.2
−29.3 ± 4.9
−34
−5.3 ± 3.8
Eas Otic®
−46.2 ± 2.9
−3.0 ± 8.7
−17.7 ± 14.7
−22.3
2.7 ± 6.5
Epi Otic®
−9.2 ± 3.1
−12.4 ± 3.2
−11.8 ± 2.5
−11.2
−7.1 ± 2.0
Otifree®
−8.1 ± 4.3
−3.5 ± 2.7
−10.3 ± 5.6
−7.3
5.6 ± 1.2
Otomax®
−68.6 ± 6.7
−19.3 ± 10.0
−22.7 ± 6.3
−36.9
−18.5 ± 3.0
Panolog®
−57.8 ± 10.4
−15.5 ± 5.8
−34.7 ± 8.4
−36
−5.4 ± 7.1
Posatex®
−58.2 ± 10.8
−32.4 ± 11.8
−47.4 ± 9.9
−46
−64.4 ± 5.5
Surolan®
−20.4 ± 8.6
−19.4 ± 7.5
−23.5 ± 8.8
−21.1
−3.7 ± 7.1
Control (water) −2.5 ± 1.1 −3.4 ± 1.6 −2.6 ± 1.0 −2.8 −2.1 ± 3.3

* Weighing was performed after washing with cold water (mean ± standard deviation), n = 4 loadings per test.

Positive values indicate ceruminolysis; negative values indicate that there has been impregnation of the product.